Orion Ion Selective Electrodes. Thermo Scientific-ORION 9429BN
SKU: ORION 9429BN
Construction: Solid state half-cell Species: Cupric (Cu2+) Connector: BNC (4) Concentration Range: 0.1 to 10-8 M, 6350 to 6.4 x 10-4 ppm Temp Range: 0 - 80 °C Use Reference: 900200 Ref. Fill Sol'n: 900003 outer Cal. Stds.: 942906$1,220.00Sales Unit: EACH
-
Orion ISE Calibration Standards. Thermo Scientific-ORION 942906
SKU: ORION 942906
For Cupric Electrode, 0.1 M Cu(NO3)2$165.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9417SC
SKU: ORION 9417SC
Solid state half-cell Species: Chloride (Cl-) Connector: Screw Cap (2) Concentration Range: 1.0 to 5 x 10-5 M, 35,500 to 1.8 ppm Temp Range: 0 - 80 °C Use Reference: 900200 Ref. Fill Sol'n: 900003 outer Cal. Stds.: 941706, 941707, or 94171...$919.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9417BN
SKU: ORION 9417BN
Solid state half-cell Species: Chloride (Cl-) Connector: BNC (4) Concentration Range: 1.0 to 5 x 10-5 M, 35,500 to 1.8 ppm Temp Range: 0 - 80 °C Use Reference: 900200 Ref. Fill Sol'n: 900003 outer Cal. Stds.: 941706, 941707, or 941709 Req'...$915.00Sales Unit: EACH
-
Orion ISE Calibration Standards. Thermo Scientific-ORION 941708
SKU: ORION 941708
For Chloride Electrode, 1000 ppm as Cl-$101.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9416BN
SKU: ORION 9416BN
Solid state half-cell, Silver/Sulfide (Ag⁺/S²⁻), BNC connector (4). Concentration range: 1.0 to 10⁻⁷ M, 107,900 to 0.01 ppm (Ag⁺); 32,100 to 0.003 ppm (S²⁻). Temp range: 0-80°C. Use Ref: 900200. Ref. Fill: 900002 inner, 900003 outer.$978.00Sales Unit: EACH
-
Orion ISE Calibration Standards. Thermo Scientific-ORION 941706
SKU: ORION 941706
For Chloride Electrode, 0.1 M NaCl$143.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9409SC
SKU: ORION 9409SC
Solid state half-cell Species: Fluoride (F-) Connector: Screw Cap (2) Concentration Range: Saturated to 10-6 M, saturated to 0.02 ppm Temp Range: 0 - 80 °C Use Reference: 900100 Ref. Fill Sol'n: 900001 Cal. Stds.: 940906, 940907, '040906, ...$918.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9409BN
SKU: ORION 9409BN
Solid state half-cell Species: Fluoride (F-) Connector: BNC (4) Concentration Range: Saturated to 10-6 M, saturated to 0.02 ppm Temp Range: 0 - 80 °C Use Reference: 900100 Ref. Fill Sol'n: 900001 Cal. Stds.: 940906, 940907, '040906, 040907...$979.00Sales Unit: EACH
-
Orion ISE Calibration Standards. Thermo Scientific-ORION 940906
SKU: ORION 940906
For Fluoride Electrode, 0.1 M NaF$120.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9406BN
SKU: ORION 9406BN
Solid state half-cell Species: Cyanide (CN-) Connector: BNC (4) Concentration Range: 10-2 to 8 x 10-6 M, 260 to 0.2 ppm Temp Range: 0 - 80 °C Use Reference: 900200 Ref. Fill Sol'n: 900002 inner, Cal. Stds.: Consult manual Req'd ISA Sol'n: ...$1,350.00Sales Unit: EACH
-
Orion Ion Selective Electrodes. Thermo Scientific-ORION 9320BN
SKU: ORION 9320BN
Plastic membrane half-cell, Calcium (Ca²⁺), BNC connector (4). Concentration range: 1.0 to 5.0 x 10⁻⁷ M, 40,100 to 0.02 ppm. Temp range: 0-40°C. Use Ref: 900100. Ref. Fill: 900011. Cal Stds: 922006, 923206. Req’d ISA: 932011$1,630.00Sales Unit: EACH